Addressing Rouge in Biopharmaceutical Manufacturing Systems


Equipment and Processing Report

Untitled Document

Stainless steel is the primary construction material for pharmaceutical and biopharmaceutical processing equipment. Prized for its ability to resist corrosion, stainless steel comes in hundreds of types and subtypes. Austenitic stainless steel is the most common type in these applications. It is nonhardened, nonmagnetic, and easily welded, and it resists heat and chemical sterilization and corrosion. The most common austenitic stainless steels are 304, 304L, 316, and 316L. “L” refers to low carbon content (i.e., 0.03% instead of 0.08%). The base metal of 304 and 316 stainless steels is iron (62–65%), which is combined with chromium (16–20%), nickel (8–14%), and other components such as carbon, silicon, and molybdenum (1).

Stainless steel becomes corrosion-resistant during a process called self-passivation, when the metal surface, which must be clean, comes into contact with oxygen to form a nonreactive chromium-enriched passive layer. In addition to naturally occurring passivation, chemicals such as nitric acid, phosphoric acid, citric acid, and formulated phosphoric acid–citric acid blends can passivate stainless steel (2–4).

Figure 1: X-ray photoelectron spectroscopy analysis graph. Image is courtesy of the author.
Figure 1: X-ray photoelectron spectroscopy analysis graph. Image is courtesy of the author.

The quality of the passive layer can be assessed through various methods, including X-ray photoelectron spectroscopy (XPS). XPS commonly helps scientists validate chemical treatments. Before passivation, operators rinse mechanically polished stainless-steel panels with isopropyl alcohol, high-purity water, acetone, and again with high purity water. After passivation treatment, operators remove the panels, rinse them with high-purity water, and allow them to air dry. Figure 1 shows the results of an XPS analysis (5, 6). The chromium–iron ratio at the surface of the untreated sample is approximately 0.25 Å, while that of the samples treated with formulated or commodity citric acid is approximately 2.0 Å.

Types and causes of rouge
Rouge is a corrosion product of stainless steel that ranges in color from reddish brown to blue or black. The general types of corrosion are galvanic, pitting, stress, intergranular, crevice, and microbe-induced. Rouge can be classified into the following three types (7, 8):

  • Type I: Oxidized metal particles, generated by an external source through erosion or corrosion, that are deposited on downstream surfaces. This rouge generally is easy to wipe off, leaving the underlying stainless-steel surface intact (see Figure 2).
  • Type II: Rougecaused by in situ oxidation, which generally adheres strongly and sometimes indicates underlying surface damage or pits.
  • Type III: Black-oxide rouge generated by high temperatures or steam. The top layers of this rouge wipe off, but full removal often requires specific chemical treatment.
Figure 2: Pipe with type I rouge. Image is courtesy of the author. Photo by Amanda Deal.
Figure 2: Pipe with type I rouge. Image is courtesy of the author. Photo
by Amanda Deal.

Rouge occurs in most biopharmaceutical facilities and often is associated purified-water systems, clean-steam systems, buffer-preparation tanks (especially sodium-chloride or glycine-solution preparations), filling lines, vial washers (which typically are cleaned with hot purified water), and steam sterilizers. Rouge results from exposure to highly aggressive environments such as purified-water or -steam systems, chloride or corrosive products, and high-temperature stress or erosion. Other factors that cause rouge are nonstainless-steel components or inserts, improper welding, surface defects, and inadequate cleaning or passivation.

Consistent procedures reduce downtime
Facilities should have procedures in place for cleaning, derouging, and passivating new equipment, as well as for periodically inspecting in-use water systems and process equipment. New equipment often arrives with particulates and oily residues from buffing, polishing, and lubricating compounds. These residues must be removed, and the chromium-enriched passive layer restored.

Qualified engineering or maintenance staff should inspect in-use equipment for rouge. Surface inspection will help determine whether the equipment needs to be derouged and passivated. If no program is in place, a semiannual inspection is recommended as a starting point.

Laboratory evaluation can help determine the best conditions (e.g., chemistry, concentration, time, and temperature) for removing specific types of rouge. A facility’s routine acid cleaner, when used at a higher concentration and for a longer time, may effectively remove the rouge and restore the passive layer.

Low-level preventive derouging and passivation
Formulated alkaline cleaners are effective at removing most biopharmaceutical-process residues from stainless-steel surfaces. The standard approach for routine cleaning is to remove organic residues with an alkaline cleaner and perform an acid rinse to remove inorganic residues and neutralize the alkaline cleaner. Although this acid rinse is performed at a lower concentration and for less time than during derouging and passivation, it also can be an effective method for removing rouge and enhancing the passive layer (see sidebar, “The general procedure for derouging and passivation of 304 and 316 stainless-steel surfaces.”) (9).

The general procedure for derouging and passivation of 304 and 316 stainless-steel surfaces.
  1. Determine the type of rouge that is present. A laboratory evaluation is recommended.
  2. Preclean the surface with formulated alkaline chemistry as appropriate.
  3. Charge the system with a 10% concentration of formulated phosphoric or citric-acid-based detergent at 80 °C.
  4. Measure the initial iron concentration in the solution.
  5. Repeat the iron measurement at set intervals until a plateau is reached.
  6. Add formulated phosphoric or citric-acid-based detergent to a level of at least 15%.
  7. After a set interval, measure the iron concentration again.
  8. If the iron concentration did not increase significantly, continue agitation for three hours at 80 °C.
  9. Repeat steps 5–8 until the surface appears visually clean or until no additional iron is removed from the surface.
  10. Drain the equipment, rinse it thoroughly with high-quality water, and blow it dry with clean compressed air or allow it to air dry.

The author generated laboratory rouge by suspending a preweighed 304 stainless-steel coupon and mild steel coupon in a 1% sodium-chloride solution while mixing for one week. The laboratory-generated rouged coupons were then treated with water, citric acid, formulated citric acid, or phosphoric-acid detergent at 60 °C for 30 min. The results, shown in Figure 3, indicate that low-level concentration and temperature conditions can remove rouge.

The removal of laboratory-generated rouge with water, citric acid, formulated citric acid, and phosphoric or citric-acid detergents. Image is courtesy of the author.
The removal of laboratory-generated rouge with water, citric acid, formulated citric acid, and phosphoric or citric-acid detergents.
Image is courtesy of the author.

A low-concentration acid rinse after an alkaline wash step has potential benefits for regular preventive maintenance, derouging, and passivation. Compared with removing the equipment from the production line completely to deal with rouge buildup, a low-level clean-in-place approach can save time, cost, and labor in the long run. In addition, preventive-maintenance programs that include routine inspection of equipment surfaces and piping, and specific derouging and passivation procedures, can reduce costly equipment downtime significantly.

References

  1. M.M. Gonzalez, Pharm. Eng. 21 (5), 48–63 (2001).
  2. ASME, “Nonmandatory Appendix E: Passivation Procedure Qualification,” in BPE – 2009 Bioprocessing Equipment (ASME, New York, 2009), pp. 185–194.
  3. ASTM, A 967 – 99, Standard Specification for Chemical Treatments for Stainless Steel Parts (ASTM, West Conshohocken, PA, 2001), pp. 1–6.
  4. ASTM, A 380 – 96, Standard Practice for Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems (ASTM, West Conshohocken, PA, 1996), pp. 1–12.
  5. STERIS, “Lab Report 410-300-3308, The Effect of ProKlenz TWO on Passivation of 316 Stainless Steel,” (STERIS, Mentor, OH, 2009).
  6. P. Lopolito, INTERPHEX Puerto Rico 2010 (San Juan, Puerto Rico, 2010).
  7. R.E. Avery and R.K. Raney, Eur. J. Parenter. Pharm. Serv. 13 (1), 21–24 (2008).
  8. J.C. Tverberg and J.A. Ledden, Proceedings of Tube 2000 (Dusseldorf, 2000).
  9. STERIS, “Lab Report 410-300-3313, Laboratory Derouging of Simulated Rouge Using ProKlenz TWO,” (STERIS, Mentor, OH, 2009).

Paul Lopolito is a technical services specialist at STERIS, Mentor, OH, paul_lopolito@steris.com.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
FDASIA was signed into law two years ago. Where has the most progress been made in implementation?
Reducing drug shortages
Breakthrough designations
Protecting the supply chain
Expedited reviews of drug submissions
More stakeholder involvement
Reducing drug shortages
29%
Breakthrough designations
8%
Protecting the supply chain
42%
Expedited reviews of drug submissions
8%
More stakeholder involvement
13%
View Results
Jim Miller Outsourcing Outlook Jim Miller Health Systems Raise the Bar on Reimbursing New Drugs
Cynthia Challener, PhD Ingredients Insider Cynthia ChallenerThe Mainstreaming of Continuous Flow API Synthesis
Jill Wechsler Regulatory Watch Jill Wechsler Industry Seeks Clearer Standards for Track and Trace
Siegfried Schmitt Ask the Expert Siegfried SchmittData Integrity
Sandoz Wins Biosimilar Filing Race
NIH Translational Research Partnership Yields Promising Therapy
Clusters set to benefit from improved funding climate but IP rights are even more critical
Supplier Audit Program Marks Progress
FDA, Drug Companies Struggle with Compassionate Use Requests
Source: Equipment and Processing Report,
Click here