Faster testing can improve efficiency of both the laboratory and the overall manufacturing process. This month's featured products are designed to be easier to use and to produce results faster while maintaining accuracy. A total organic carbon (TOC) analyzer from Swan Analytical measures TOC in pure and ultrapure water. A direct sample analysis system from Perkin Elmer eliminates sample preparation steps. A light-weight, portable particle counter from Kanomax has an increased flow rate.

Total organic carbon analyzer tests pharmaceutical water


AxION Direct Sample Analyzer and AxION TOF Mass Spectrometer System PerkinElmer www.perkinelmer.com
Swan Analytical's AMI Line total organic carbon (TOC) analyzer is designed for continuous, accurate measurement of TOC in pure and ultrapure water in the pharmaceutical industry. The instrument has a range of 0.1–1000 ppb TOC and a resolution of O.1 ppb. TOC is measured using UV oxidation and differential conductivity detection, with results in less than two minutes. The analyzer is designed for ease of performing a system suitability test (SST). Standard sucrose or benzoquinone solutions are automatically added, and grab samples can be taken by pushing a button. In addition, automatic sensor verification uses less expensive, durable, concentrated standards that are automatically diluted, which allows the user to verify the accuracy of the measurement without performing a SST. The analyzer's electronic drift stabilization provides long term, stable analysis results.

System reduces sample preparation for mass spectrometry


AMI Line TOC analyzer Swan Analytical www.swan-analytical-usa.com
PerkinElmer's AxION Direct Sample Analysis (DSA) system is designed to introduce liquid, solid, and gas samples directly to PerkinElmer's AxION Time-of-Flight (TOF) mass spectrometer. The DSA system eliminates sample preparation steps and removes the need for front-end gas or liquid chromatography separation because samples can be directly introduced to the mass spectrometer. Using the DSA system reduces sample preparation time from a typical 25 min. down to 25 s. The integrated DSA system is entirely enclosed to prevent atmospheric contamination of samples and fully automated for fast data acquisition.

Portable particle counter is easy to transport


Model 3910 50LPM Portable Particle Counter Kanomax www.kanomax-usa.com
The Kanomax Model 3910 50LPM Portable Particle Counter can simultaneously measure six particle sizes in tasks such as cleanroom verification, clean bench verification, filter testing, and facility certification. The model is designed to be small and light so that it is easy to transport and manage in the field. This model has an increased, 50 L/min flow rate, which increases testing speed. The unit has a stainless steel enclosure and is compliant with ISO 21501-4 and 21 CFR Part 11. The instrument features an intuitive, LCD touch screen and preprogrammed standards, and stores up to 10,000 measurements. An optional Climomaster probe measures air velocity, temperature, and humidity.

ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
What is the single greatest threat to maintaining manufacturing processes at your facility?
Quality issues
Facility/environment problems
Process development problems
Production equipment downtime
Raw material supply problems
Regulatory restrictions
Business decisions to limit production
Quality issues
50%
Facility/environment problems
0%
Process development problems
0%
Production equipment downtime
17%
Raw material supply problems
17%
Regulatory restrictions
0%
Business decisions to limit production
17%
View Results
UPCOMING CONFERENCES

Programs for Investigational and Pre-Launch Drugs
Philadelphia, PA
July 17-18, 2013
Request Brochure

Strategic Pipeline Planning & Portfolio Valuation
Philadelphia, PA
August 13-14, 2013
Request Brochure

MES 2013 - Forum on Manufacturing Execution Systems
Philadelphia, PA
August 14-15, 2013
Request Brochure

Mobile Innovation for the Life Sciences Industry
Philadelphia, PA
August 20-21, 2013
Request Brochure

See All Conferences >>

Eric Langer Outsourcing Outlook Eric LangerOutsourcing's Modest Role as a Cost-Containment Strategy
Patricia Van Arnum Ingredients Insider Patricia Van ArnumIntellectual Property Battles in Solid-State Chemistry
Nathan Jessop Industry Insider Nathan Jessop Campaign Against Counterfeit Drugs Continues
Lynn Torbeck Statistical Solutions Lynn D. TorbeckCompositing Samples and the Risk to Product Quality
 More
Patent Settlements Become More Risky
Praise and Perils for Biotechnology Patent Policy
Risk-Mitigation Strategies in Drug Manufacturing for Emerging Markets
Quality Focus: Ensuring Raw Material Transparency
Advertising of Prescription Drugs  Keeping it Honest and Balanced
Source: Pharmaceutical Technology,
Click here