Regulations governing sterile manufacture of pharmaceuticals have been significantly revised since their introduction. The recent amendment to Annex 1 has seen the most controversial changes relating to the capping of vials. Pharmaceutical Inspection Cooperation Scheme has provided an interpretation of the guidelines and has published a report that offers advice on how to comply with the new recommendations. Capping is the particular focus of this article.


Pharmaceutical Technology Europe
Volume 22, Issue 8


GETTY IMAGES/CHRISTINE BALDERAS
Regulations governing the manufacture of sterile pharmaceuticals in the US and Europe have been significantly revised over the past few years. The first milestone was set by the FDA's Guidance for Industry Sterile Drug Products Produced by Aseptic Processing" — "Aseptic Guide in 2004. In 2008, four parts of the EU GMP Guide Annex 1 Manufacture of Sterile Medicinal Products were extensively revised. Annex 1 became fully effective on 3 January 2010.

Another important document that often receives little attention is the PIC/S (Pharmaceutical Inspection Cooperation Scheme; http://www.picscheme.org/) recommendation PI 0075 "Validation of Aseptic Processes". Primarily aimed at pharmaceutical inspectors, this document also aids the pharmaceutical user in the interpretation and implementation of the new Annex 1 standards. In the course of the Annex 1 revision, the PIC/S document underwent several revisions and now corresponds with the current guideline.

The revised version of EU GMP Guide Annex 1 Manufacture of Sterile Medicinal Products

The revised version of Annex 1 primarily applies to four partial aspects:
  • Clean room and clean air device classification
  • Process simulation / media fill
  • Bioburden monitoring
  • Finishing of sterile products

Clean room and clean air device classification has been developed to be harmonised with the standard EN ISO 14644. For Process simulation / media fill the requirements were harmonised with the standards of the FDA Aseptic Guide. These standards were also adopted in the PIC/S document PI 007-5. The specifications for Finishing of sterile products generated a much higher need for text interpretation. The new specifications, particularly for capping vials, have also caused uncertainty for inspectors in the pharmaceutical industry.

To eliminate this uncertainty, the PIC/S published another document in January 2010, introducing the changes in Annex 1 and interpreting the new specifications. The document PIC/S recommendation PI 0322 GMP Annex 1 revision 2008, interpretation of most important changes for the manufacture of sterile medicinal products was prepared under the leadership of Swiss inspectors from Swissmedic.

The most controversial changes made to Annex 1 were found in the section for Finishing of sterile products and related to the capping of vials. Some statements in Annex 1 concerning this matter were clarified in the PIC/S document and are presented here in more detail. The PIC/S interpretations are supplemented with two case studies from pharmaceutical companies.


The author says...
Interpretations

1. "Grade A air supply" — definition, qualification and monitoring requirements (Annex 1 Section 120)

"Grade A air supply" was listed again in Annex 1 but not defined. PIC/S clearly explains the need to discern between Grade A air supply and Grade A area and defines the terms as follows:

"Grade A air supply is specifically used to describe a supply of air which is HEPA filtered, and at the point of supply meets, when tested, the non-viable particulate requirements of a Grade A area."

It is important to differentiate between the terms Grade A air supply and Grade A area. According to PIC/S, a Grade A air supply should be qualified and monitored; the qualification is to be performed in an "at rest" state. For the capping machine the "at rest" state is achieved when the air intake is switched on, the machine is operating (but without vials being fed and needing to be capped), and there is no user operation. For the transport tunnel the "at-rest" state is reached when the air intake and the conveyer are switched on and there is no user operation.

The requirements for nonliving particles are to meet Grade A area requirements. The sample is to be taken from beneath the air outlet and smoke studies are to be performed. A unidirectional air flow is not required. However, an efficient protection for the vial is to be proven, particularly an absence of ambient air entering. Rational air speed limitations should exist. Companies must determine monitoring requirements for nonliving particles and microbiological contaminations in line with a risk analysis.


ADVERTISEMENT

post a comment
Your email address will NOT be published.
appears with your comment
read our privacy policy
Note: does not support HTML
All comments submitted are subject to review, and may be delayed before posting. We reserve the right not to post comments.
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
Looking forward 10 years from now, what do you think will be the most significant change to drug development and manufacturing?
Fuller adoption of quality by design principles
Greater adoption of continuous manufacturing
A stronger movement to personalized medicine and the use of diagnostics with traditional pharmaceuticals
The rise of biologic-based drugs in commercial product portfolios and pipelines
Greater adoption of the preferred provider model in outsourcing
Fuller adoption of quality by design principles
22%
Greater adoption of continuous manufacturing
7%
A stronger movement to personalized medicine and the use of diagnostics with traditional pharmaceuticals
35%
The rise of biologic-based drugs in commercial product portfolios and pipelines
30%
Greater adoption of the preferred provider model in outsourcing
7%
View Results
Jim MillerOutsourcing OutlookJim Miller Channeling Steve Jobs
Patricia Van ArnumIngredients InsiderPatricia Van ArnumSeeking Chemocatalytic and Biocatalytic Solutions
Nathan JessopIndustry InsiderNathan Jessop Taxing Times for French Pharma
Lynn D. TorbeckStatistical Solutions Lynn D. TorbeckRepresentative Sampling
Report on Recent and Upcoming Single-Use Meetings
ICH Q11 Reaches Harmonization, Implementation is Next
Digital Signatures Growing as a Result of Part 11
Single-Cell Genomics Advancing Molecular Biology
Putting FDA’s “Process Validation” Guidance into Action
FindPharma Custom Search
Source: Pharmaceutical Technology Europe,
Click here