Setup. The experimental setup is shown in Figure 5. An aqueous continuous phase containing known amounts of l-tyrosine, potassium iodide, phosphate buffers, sodium hydroxide, and glycerin was charged to the column. The dispersed organic phase consisting of a known concentration of iodine in methylene chloride was charged to a syringe. A PTFE needle was attached to the syringe and the dispersed phase was fed into the continuous phase subsurface at a constant rate using a syringe pump. The dispersed phase (i.e., the droplet) travelled down the continuous phase and was removed from the bottom of the column by a very small effluent rate. Hydrodynamics around the droplet mixed the reactants. The volume of the continuous phase in the column remained fairly constant during a given experiment. The column was 18 in. in effective length with a 3-in. internal diameter. The column was designed with five discharge ports to allow top and bottom removal of a volume of the liquid phase. Only the middle portion of the continuous phase was used for sampling.

We developed an HPLC method to quantify and analyze the results. The HPLC method uses a linear ramp of the mobile phase to ensure peak separation and to shorten the run time of the method. All samples were analyzed with an HPLC instrument ("series 1100," Hewlett Packard) and software (ChemStation Rev. A.10.01, Agilent Technologies). The column was a 250 × 4.6 mm i.d., 5 μm C8 column (ACE, Advanced Chromatography Technologies). All samples were analyzed at a wavelength of 210 nm. The mobile phase consisted of acetonitrile (solvent A) and water containing 0.05 v% of perchloric acid and 0.1 v% of phosphoric acid (solvent B). The wavelength and solvents were chosen to minimize the run time while providing good separation and peak formation of each reaction component. (For more details, see Raffensberger [34]).


Table I: l-Tyrosine solution components.
Procedure. The aqueous l-tyrosine solution was prepared using the recipe listed in Table I. The water was saturated with methylene chloride to prevent solvent mass transfer from the dispersed phase. The resulting concentration of l-tyrosine solution used in the experiments was 0.084 ± 0.001 mg l-tyrosine/mL water.

The organic iodine solution was prepared using the recipe listed in Table II. The resulting concentration of iodine in methylene chloride was 31.7 ± 0.1 mg iodine/mL methylene chloride. The solution was aged for several hours to ensure all of the iodine had dissolved.


Table II: Iodine solution components.
Once both solutions were prepared, the continuous phase for a given experiment was made. The continuous phase was 1250 mL in volume and contained 75 mL of the l-tyrosine solution described previously. The remainder of the continuous phase consisted of water saturated with methylene chloride, glycerin, and 1.2 g each of sodium phosphate dibasic and sodium phosphate tribasic dodecahydrate. For example, a 30% glycerin solution would contain 75 mL l-tyrosine solution, 375 mL glycerin, 800 mL of deionized water saturated with methylene chloride, 1.2 g of sodium phosphate dibasic, and 1.2 g of sodium phosphate tribasic dodecahydrate. The solution was mixed for at least 5 min, and the pH and temperature of the continuous phase were checked. The pH of the continuous phase at the start was between 10 and 11. For all of the experiments reported, the starting temperature varied between 22 and 25 °C.


ADVERTISEMENT

RELATED CONTENT
Roche Recalls Viracept
Copolymerized PEGlyated Acrylate Hydrogels for Delivery of Dicolofenac Sodium
The Effect of Core and Coating Composition on Drug Release from Directly Compressed Time-Controlled Release Tablets
Near-Infrared Assay and Content Uniformity of Tablets
Maintain Your Moving Parts
blog comments powered by Disqus
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
How does your company apply quality-by-design (QbD) principles to manufacturing processes?
To all processes for both new and legacy products
To all process for new products only
To select process for new products only
To select processes for both new and legacy products
Do not use QbD
To all processes for both new and legacy products
18%
To all process for new products only
13%
To select process for new products only
22%
To select processes for both new and legacy products
22%
Do not use QbD
24%
View Results
UPCOMING CONFERENCES

Programs for Investigational and Pre-Launch Drugs
Philadelphia, PA
July 17-18, 2013
Request Brochure

Strategic Pipeline Planning & Portfolio Valuation
Philadelphia, PA
August 13-14, 2013
Request Brochure

MES 2013 - Forum on Manufacturing Execution Systems
Philadelphia, PA
August 14-15, 2013
Request Brochure

Mobile Innovation for the Life Sciences Industry
Philadelphia, PA
August 20-21, 2013
Request Brochure

See All Conferences >>

Eric Langer Outsourcing Outlook Eric LangerOutsourcing's Modest Role as a Cost-Containment Strategy
Patricia Van Arnum Ingredients Insider Patricia Van ArnumIntellectual Property Battles in Solid-State Chemistry
Nathan Jessop Industry Insider Nathan Jessop Campaign Against Counterfeit Drugs Continues
Lynn Torbeck Statistical Solutions Lynn D. TorbeckCompositing Samples and the Risk to Product Quality
 More
Inadequate Access to Medicines Puts EU at Risk
FDA Offers Insight on QbD for Modified-Release Products
Global Biosimilars Market to Reach $2.445 Billion in 2013
Adapting to Change
AstraZeneca and Exco InTouch Collaborate to Augment Current COPD Pathways
FindPharma Custom Search
Source: Pharmaceutical Technology,
Click here