The authors applied near-infrared (NIR) spectrophotometry to assess whether eight drug products were authentic or counterfeit.


Pharmaceutical Technology
Volume 33, Issue 8, pp. 46-52

Corresponding authentic product (except Cialis 50 mg), along with generic amlodipine besylate 10 mg tablets, were purchased from McKesson, a major distributor in the US.

Instrumentation. With some exceptions, NIR spectra were collected using the methods of Tatavarti et al. (9). The authors used an RCA XDS NIR spectrometer (Foss NIRSystems, Columbia, MD) to collect the spectra. Instrument operation and data analysis were performed using Foss's Vision 3.2 software. The data-collection method was set to full range (400–2500 nm). Samples and references were scanned in diffuse-reflectance mode an average of 32 times at 0.5-nm intervals. In addition, NIR spectra were collected using a PHAZIR-Rx instrument (Polychromix, Wilmington, MA).




NIR spectra comparison. The authors compared the NIR spectrum of each suspected counterfeit product to that of the authentic product using the ρm criterion expressed in the following equation (10, 11):




where R t is the absorbance of the reference product at wavelength t, T t is the absorbance of the test product at wavelength t, and RATIO t is the larger of either R t ÷ T t or T t ÷ R t. Previously, ρm has been used to compare test and reference profiles (e.g., plasma profiles and dissolution profiles) and assess profile similarity. ρm is weighed by the sum of R t and T t. This weighting factor places more emphasis on the wavelengths with higher absorbtivities. The unweighted criterion is:




Spectra were also compared by the following Deltaa metric (10, 11):




in which δa is based upon the absolute difference between two spectra and considers the relative size of the profiles. For profiles that are not identical, 0 ≤ δa. In equation 3, δa is weighed by R t + T t. The unweighted criterion is:

Other quality tests. As discussed below, a simple visual inspection of test Cialis 50 mg resulted in the conclusion that it was counterfeit, and disintegration testing was performed using the US Pharmacopeia method. Disintegration was also conducted on the reference Cialis 20 mg for comparison purposes because authentic Cialis is not available in 50-mg strength.


Figure 1. Test Cialis 50 mg package. The plastic container appeared to be of low quality and failed to denote tablet quantity, manufacturer, and distributor. The packaging included a "Lilly" hologram and a misspelled "Lieel icos" marking.
In addition, when an authentic active pharmaceutical ingredient (API) was available, thin-layer chromatography (TLC) was conducted on the test and reference products. TLC was performed on amlodipine besylate, sildenafil citrate, and terbinafine hydrochloride products. Tablets were crushed and subjected to TLC in parallel with the authentic APIs. A 0.3mg/mL solution of drug in methanol was prepared for amlodipine besylate products and API and run on a TLC plate using a mixture of 2-butanone, water, and glacial acetic acid in a ratio of 50:25:25 as the mobile phase. For the sildenafil citrate products and API, a 1mg/mL solution of drug in methanol was prepared and run on a TLC plate using the same mobile phase. Terbinafine hydrochloride products and API were evaluated using the same method as that for sildenafil citrate. Plates were inspected under ultraviolet light at 254 nm.


ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
How does your company apply quality-by-design (QbD) principles to manufacturing processes?
To all processes for both new and legacy products
To all process for new products only
To select process for new products only
To select processes for both new and legacy products
Do not use QbD
To all processes for both new and legacy products
20%
To all process for new products only
13%
To select process for new products only
24%
To select processes for both new and legacy products
20%
Do not use QbD
22%
View Results
UPCOMING CONFERENCES

Programs for Investigational and Pre-Launch Drugs
Philadelphia, PA
July 17-18, 2013
Request Brochure

Strategic Pipeline Planning & Portfolio Valuation
Philadelphia, PA
August 13-14, 2013
Request Brochure

MES 2013 - Forum on Manufacturing Execution Systems
Philadelphia, PA
August 14-15, 2013
Request Brochure

Mobile Innovation for the Life Sciences Industry
Philadelphia, PA
August 20-21, 2013
Request Brochure

See All Conferences >>

Eric Langer Outsourcing Outlook Eric LangerOutsourcing's Modest Role as a Cost-Containment Strategy
Patricia Van Arnum Ingredients Insider Patricia Van ArnumIntellectual Property Battles in Solid-State Chemistry
Nathan Jessop Industry Insider Nathan Jessop Campaign Against Counterfeit Drugs Continues
Lynn Torbeck Statistical Solutions Lynn D. TorbeckCompositing Samples and the Risk to Product Quality
 More
Inadequate Access to Medicines Puts EU at Risk
FDA Offers Insight on QbD for Modified-Release Products
Global Biosimilars Market to Reach $2.445 Billion in 2013
Adapting to Change
AstraZeneca and Exco InTouch Collaborate to Augment Current COPD Pathways
FindPharma Custom Search
Source: Pharmaceutical Technology,
Click here