A Project Manager's Perspective.


Pharmaceutical Technology


Getting started. The choice of a syringe system should be a critical part of the regulatory strategy and must be considered at the outset, perhaps even with product reformulation. The syringe system is important because a packaging system that is acceptable for one therapeutic will not necessarily work for another because of differences in dosing ranges, patient populations, and in how individual molecules react to surrounding materials and conditions. Evaluation of the proposed syringe system must consider these factors, and regulatory submissions must support the suitability of the proposed packaging and storage conditions.

An analysis of proposed syringe systems should take into account their appropriateness, functionality, and materials. First, the dosing device has to be suitable, and its graduations appropriate, for the intended patient population. At a basic level, the syringe must deliver the dose in the amount and rate stipulated in the package insert. In addition, the physical characteristics of the liquid drug formulation must be appropriate for the dosing device to ensure accurate dispersion of the drug through the needle.

Second, the proposed system must function correctly throughout its shelf life. The results of coating integrity testing, effect of viscosity, and syringe-ability must be considered. Moreover, scale intervals on the syringe must represent the labeled dosages, and gradations in dose must be easily read. The type should be embossed or printed and legible throughout the shelf life of the product. These markings cannot fade or become dislocated during the use or life of the product. In addition, stopper movement during use, as well as the effect of shipping on stopper movement, must be considered to ensure sterility of the product and to avoid particulate contamination.

Third, materials in the proposed syringe must be compared with those of the current vial. The analysis should consider whether:
  • The material in the proposed syringe, including in the container, plunger device, and closure system, protects the drug product
  • The syringe system introduces a new material
  • The system will require any changes to the drug product formulation.

Choosing a container and closure system made of the same materials as the vial will eliminate the need for additional extractable and leachable studies. Any new materials, including those in the hub or needle, will need to be evaluated in stability testing. Extractable studies also must include proposed labels, adhesive, and ink if the barrel of the syringe is not made of glass.

Stability protocol. FDA rules governing current good manufacturing practice (GMP) stipulate that companies develop and thoroughly document a testing program to assess the stability characteristics of the drug product (9). Consequently, a company must define stability testing requirements related to the container–closure system. These requirements include how temperature, humidity, and light influence the shelf life of the drug and help to determine appropriate storage conditions and expiration dates for the product. A stability protocol that is specific to the molecule and the proposed drug-delivery device must be written, implemented, and evaluated to assess the stability characteristics of the molecule in the container–closure system (9).


Table III: Filing requirements for prefilled syringes.
Although some extractable and leachable studies related to the dry or liquid vial presentation may be transferable to the new format, some new stability testing is required when moving an injectable therapeutic to a prefilled syringe (see Table III). The long, narrow dimensions of a syringe increase the molecule-to-surface-area ratio from the previous vial presentation. As a consequence, accelerated and long-term stability studies are necessary to determine whether the change affects the extractable and leachable parameters and to understand the impurity and degradation profile of the molecule in the container–closure system.

The stability protocol should detail the sample size, test intervals, storage conditions, validated analytical methods to be performed, the container–closure system, test specifications, and number of batches required. In addition, reconstitution studies will be required for parenteral products offered in a kit with a prefilled diluent syringe or in a dual-chamber prefilled lyophilized syringe. Tests and specifications must be based on knowledge of the degradation pathway for the particular molecule, use validated and stability-indicating methods, and specify limits appropriately.

Clinical testing. Clinical studies are required when there is a change in indication or new route of administration for the drug. However, movement from a dry or liquid vial to a prefilled syringe also necessitates clinical testing if the reformulated drug's degradation or impurities profile change.


ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
Which of the following business challenge poses the greatest threat to your company?
Building a sustainable pipeline of products
Attracting a skilled workforce
Obtaining/maintaining adequate financing
Regulatory compliance
Building a sustainable pipeline of products
27%
Attracting a skilled workforce
27%
Obtaining/maintaining adequate financing
14%
Regulatory compliance
32%
View Results
Eric Langer Outsourcing Outlook Eric LangerBiopharma Outsourcing Activities Update
Cynthia Challener, PhD Ingredients Insider Cynthia Challener, PhDAppropriate Process Design Critical for Commercial Manufacture of Highly Potent APIs
Jill Wechsler Regulatory Watch Jill Wechsler FDA and Manufacturers Seek a More Secure Drug Supply Chain
Sean Milmo European Regulatory WatchSean MilmoQuality by Design?Bridging the Gap between Concept and Implementation
Report: Pfizer Makes $101 Billion Offer to AstraZeneca
Medicare Payment Data Raises Questions About Drug Costs
FDA Wants You!
A New Strategy to Tackle Antibiotic Resistance
Drug-Diagnostic Development Stymied by Payer Concerns
Source: Pharmaceutical Technology,
Click here