Results

Design-of-experiments interpretation. The mathematical model generated for each response Y was a quadratic model with first-order interactions, built according to the following equation:




in which X i and X j represent the levels of the factors; a 0 is the intercept representing the mean of the measured response data; and a i and a j , a ii and a jj , and a ij correspond to the coefficients of first-order terms, the coefficients of second-order quadratic terms, and the coefficient of second-order interaction terms, respectively. The coefficient corresponding to a factor or interaction shows its importance on the studied response. The symbol ε represents pure error. For the multilevel categoric factors presenting more than two levels (i.e., factor E), the software calculates two coefficients, E(1) and E(2), of the difference between the overall average and the high and low levels, respectively. To simplify the design-of-experiments interpretation, the coefficients of second-order quadratic terms were not presented in this study. The coefficient values were expressed in coded units to compare their relative effect to that of the others.


Figure 3: Effects of factors and main interactions on various responses.
Analysis of variance (ANOVA) was performed to determine the significance of the model. A probability value lower than 0.05 was considered significant. A probability value greater than 0.10 was regarded as not significant. The effects of factors and main interactions between the factors, deduced from the analysis of the experimental design, are summarized with bar graphs on Figure 3. The red bars correspond to the factors that significantly influenced the response Yx.

Influence of formulation. As deduced from the analysis of the experimental design (see Figure 3), the drug substance solubility (D) and concentration (A) had significant influence on all the responses except pellet elongation and roughness index for the drug concentration. Some of these effects can be explained by the different water quantities required for different formulations.

Decreases in drug concentration and solubility both led to a lower extrusion rate and yield. The corresponding water quantity increase should nevertheless facilitate extrusion by an extrusion force decrease due to a lubricant effect (1–3, 5, 10, 28, 32, 37, 38). The observed effect is more likely linked to raw materials properties and facilities to extrude than to associated water quantities. Decreases in drug concentration and solubility also decreased pellet size and the usable yield fraction, and increased true density, friability, and hardness. The drug-solubility decrease also increased pellet elongation and rugosity by decreasing the solidity index. These effects can be explained by the corresponding water quantity increase. Many authors reported that water evaporation from wet pellets during the oven-drying step caused a mechanical shrinkage phenomenon (15, 39–44). Shrinkage proportional to the water-quantity increase led to a particle size reduction (and thus a decrease in usable yield fraction), a decrease in circularity decrease, a roughness increase and subsequent friability increase by attrition, and densification leading to an increase in hardness.

Drug concentration and solubility thus had a similar influence on the responses, including an important effect on drug solubility. Except for pellet friability, an interaction between the two formulation variables was observed for all the responses. Some authors also indicated an interaction between the two formulation variables and observed higher impact of drug solubility on the different responses, because it led to greater differences between the corresponding water quantities than for DS concentration (3, 4). Moreover, drug concentration had more influence for the highly soluble drug, where large changes in water quantity are required for different concentrations, than for the poorly soluble drug, where water quantities remain very similar.


Table I: Analysis of the influence of extrusion system on responses to drug substance solubility and concentration.
Influence of the extrusion system. The extrusion system had a significant effect on all responses. Significant interactions between the extrusion system and drug substance solubility and concentration and their effect on the responses necessitated that formulations were analyzed as distinct designs of experiments. This method enabled identification of the extruder type that gave the best results in terms of process and pellet quality, according to the formula (see Table I).

For example, in the formulation constituting 36% DS1, the dome system had the highest extrusion rate, and the axial system had the lowest extrusion rate. Analysis of the extrusion system influence showed different results according to the formulation tested. The extrusion systems presented more significant differences for DS2 than for DS1 on pellet properties. Overall, the axial system presented the best results in terms of pellet yield, mechanical properties, and roughness, followed by the dome system for productivity and pellet circularity. The radial system produced the worst results irrespective of the formulation.

Influence of spheronization conditions. The design of experiments showed a significant effect of spheronization speed and time on some pellet characteristics, as shown on Figure 3. An increase in spheronization speed influenced the pellet usable yield fraction, roughness index, and hardness, whereas spheronization time influenced pellet size, elongation, roughness index, true density, and hardness. Both factors increased pellet hardness to the same degree, as observed previously (26, 46–48). This result most likely can be explained by pellet densification caused by the pellet water migration during spheronization, which decreases pellet porosity after drying (21). An increase in spheronization speed decreased the usable yield fraction, probably because of the phenomenon of attrition linked to increases in rugosity (28, 35). On the other hand, as reported by other authors, spheronization time increased pellet size and quality by improving pellet roundness and decreasing pellet rugosity (17, 22, 26, 28, 34, 36, 49). Nevertheless, spheronization time decreased the pycnometric density, which can be explained by pores closing on the surface during spheronization, thus creating internal porosity.


ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
What role should the US government play in the current Ebola outbreak?
Finance development of drugs to treat/prevent disease.
Oversee medical treatment of patients in the US.
Provide treatment for patients globally.
All of the above.
No government involvement in patient treatment or drug development.
Finance development of drugs to treat/prevent disease.
26%
Oversee medical treatment of patients in the US.
12%
Provide treatment for patients globally.
10%
All of the above.
43%
No government involvement in patient treatment or drug development.
10%
Jim Miller Outsourcing Outlook Jim MillerCMO Industry Thins Out
Cynthia Challener, PhD Ingredients Insider Cynthia ChallenerFluorination Remains Key Challenge in API Synthesis
Marilyn E. Morris Guest EditorialMarilyn E. MorrisBolstering Graduate Education and Research Programs
Jill Wechsler Regulatory Watch Jill Wechsler Biopharma Manufacturers Respond to Ebola Crisis
Sean Milmo European Regulatory WatchSean MilmoHarmonizing Marketing Approval of Generic Drugs in Europe
FDA Reorganization to Promote Drug Quality
FDA Readies Quality Metrics Measures
New FDA Team to Spur Modern Drug Manufacturing
From Generics to Supergenerics
CMOs and the Track-and-Trace Race: Are You Engaged Yet?
Source: Pharmaceutical Technology,
Click here