The Influence of Hydro-Alcoholic Media on Drug Release
The authors investigate the influence of hydro-alcoholic media on hydration and drug release from polyethylene oxide extended-release matrices.


Pharmaceutical Technology
Volume 35, Issue 7, pp. 50-58

Materials and methods


Table II: Polyethylene oxide extended-release formulations used in the study.
Formulation and preparation of PEO ER matrices. The influence of hydro-alcoholic media on formulations of practically water insoluble gliclazide and freely water soluble metformin HCl was investigated. Two 12-h release PEO matrix formulations were developed containing gliclazide or metformin HCl, PEO (i.e., Polyox 1105 or 301) as a matrix former, microcrystalline cellulose (MCC) as a filler, fumed silica as a flow aid, and magnesium stearate as a lubricant (see Table II). Table III shows the solubility of the drugs, polymer, and filler in water and alcohol.


Table III: Solubility of the drugs, polymer and filler used in the study, in water and alcohol (14, 33–37).
Both formulations, batch size 400 g, were blended in a shaker-mixer (Turbula, Bachofen). Microcrystalline cellulose and fumed silica were first screened through a 500 μm (35 mesh) sieve to homogenize the powder. The rest of the ingredients, except the lubricant, were added and blended for 10 min at 64 rpm. Magnesium stearate was then added and the formulations were mixed for an additional one minute.

Tablets were manufactured using an instrumented 10-station rotary tablet press (Piccola, Riva) operating at 20 rpm. Gliclazide tablets with a target weight of 200 mg were produced using 7 mm normal concave tooling at 20 kN (255 MPa). Metformin HCl matrices with a target weight of 1000 mg were manufactured using 7 18 mm concave caplet tooling at 20 kN (79 MPa).

Dissolution studies. Dissolution tests were conducted in a USP compliant dissolution bath (Sotax) using Apparatus II (i.e., paddles) with 8-mesh (2.38 mm) quadrangular baskets (QLA) in 1000 mL purified water, 5% or 40% w/v ethanol (USP/BP Hayman) solutions at 100 rpm and 37.0 0.5 C. Tablets were subjected to the hydro-alcoholic media for duration of 12 h, or 1 h followed by 11-h dissolution in water.

Absorbance was measured with a dual-beam UV–vis spectrophotometer (PerkinElmer) using 5 mm quartz cells at a wavelength of 228 nm and 0.1 mm cells at 233 nm for gliclazide and metformin HCl, respectively. Tablets were analyzed in triplicates using an automated sampling device, and mean with standard deviation values were reported.

The drug release profiles in hydro-alcoholic media were compared to those in purified water using the f 2 factor. An f 2 value between 50 and 100 indicates that the two dissolution profiles are similar (7, 38).

To investigate the mechanism of drug release in various media, the release data between 5 and 60% were fitted to the following equation (16, 39–40):




where Q is the percentage drug released at time t, k is a kinetic constant incorporating structural and geometric characteristics of the tablet and n is the diffusion exponent that indicates the drug release mechanism (39–40).

For matrix tablets, an n value close to 0.5 indicates predominantly diffusion control of drug release. An n value around 1.0 indicates erosion or relaxation control mechanism of drug release (41–42). Intermediate values suggest that both diffusion and erosion contribute to the overall release mechanism (18).

The values of n and k are inversely related, such that a decrease in n value results in a k value increase. A high k value may suggest a burst drug release from the matrix (43–44).

Preparation and testing of PEO compacts. Three viscosity grades of PEO were tested (i.e., Polyox 1105, 301, and Coagulant). PEO compacts with a target weight of 300 mg were manufactured using hydraulic automatic press (Auto T8, Atlas, Specac) and 10 mm flat-faced tooling at a compression force of 20 kN (255 MPa).

Compacts were tested in a USP-compliant AT7 Sotax dissolution bath using Apparatus II (i.e., paddles) with large (15 31 mm) sinkers (Sotax), in 900 mL of 0:100, 25:75 and 50:50 w/v ethanol:purified water mixtures at 100 rpm and 37 0.5 C.

The swelling properties of the compacts in various media were determined using a modified version of the method described by Tahara et al. and Kavanagh and Corrigan by measuring the wet weight of the hydrated PEO compacts at 15, 30, 60 and 120 mins (45, 46). Each compact was placed into a preweighed plastic container; the excess media was drained and blotted from around the tablet without touching it. The compact and the container were weighed, and the wet weight of each tablet was established. Every determination at each time point was performed in triplicate, and average and standard deviation values were calculated.

The ratio of the wet weight (W w ) to the initial weight (W i ) of the compacts was calculated, as an indication of the extent of matrix relative swelling, similar to the Panomsuk et al. approach, as described in the following equation (47):





ADVERTISEMENT

blog comments powered by Disqus
LCGC E-mail Newsletters

Subscribe: Click to learn more about the newsletter
| Weekly
| Monthly
|Monthly
| Weekly

Survey
FDASIA was signed into law two years ago. Where has the most progress been made in implementation?
Reducing drug shortages
Breakthrough designations
Protecting the supply chain
Expedited reviews of drug submissions
More stakeholder involvement
Reducing drug shortages
70%
Breakthrough designations
4%
Protecting the supply chain
17%
Expedited reviews of drug submissions
2%
More stakeholder involvement
7%
View Results
Eric Langerr Outsourcing Outlook Eric LangerRelationship-building at Top of Mind for Clients
Cynthia Challener, PhD Ingredients Insider Cynthia ChallenerRisk Reduction Top Driver for Biopharmaceutical Raw Material Development
Jill Wechsler Regulatory Watch Jill Wechsler Changes and Challenges for Generic Drugs
Faiz Kermaini Industry Insider Faiz KermainiNo Signs of a Slowdown in Mergers
From Generics to Supergenerics
CMOs and the Track-and-Trace Race: Are You Engaged Yet?
Ebola Outbreak Raises Ethical Issues
Better Comms Means a Fitter Future for Pharma, Part 2: Realizing the Benefits of Unified Communications
Better Comms Means a Fitter Future for Pharma, Part 1: Challenges and Changes
Source: Pharmaceutical Technology,
Click here