 Figure 4: Half-normal plot of tablet weight.
|
Weight response.
Tablet weight is a crucial tablet characteristic, and data analysis is necessary for this response. The half-normal plot
for tablet weight using the original screening results is shown in Figure 4. The plot indicates that factors A, B, C, and
E significantly affected the weight response. The analysis of variance shown in Table VI supports the plot in Figure 4.
In the next equation, R
2
is 0.9955, adjusted R
2
is 0.9945, and adequate precision is 126.423. The R
2
of 0.9955 is in reasonable agreement with the adjusted R
2
of 0.9945. The adequate precision ratio of 126.423 indicates an adequate signal, so the following equation, in terms of coded
factors, can be used to establish the design space:
 Figure 5: Normal plot of residuals for weight.
|
The 95% confidence intervals for the coefficients of each of the significant terms were verified to exclude zero, which supports
the determination that all identified factors in the model equation influence the response. A normal plot of residuals was
constructed to determine whether the distribution was normal (see Figure 5).
 Figure 6: Residuals versus predicted plot for weight.
|
A residuals versus predicted plot was constructed to look for trends in the data (see Figure 6). All data points are equally
distributed and are within two standard deviations from the mean, with two exceptions. One high point is 2.422 standard deviations,
and one low point is –2.473 standard deviations). The two data points that lie beyond 2 standard deviations of the mean could
be investigated, and these experiments may warrant being rerun to confirm the data response. The data have no potential outliers.
 Appendix Figure 5: One-factor plot, tablet weight versus fill-cam height.
|
No two-factor interactions can be plotted, though factor E (i.e., fill-cam height and weight-adjustment ramp) had a significant
effect on tablet weight. As can be expected, the amount of powder placed into the die cavity had a direct effect on tablet
weight. This is clearly evident in Appendix Figure 5. The plot shows that as the weight ramp or fill cam height is increased,
tablet weight increases.
|